gentleMACS™ Tissue Dissociators and Tubes offer everything you need to reliably obtain viable single cells from any tissue. The combination of gentleMACS Tubes and Dissociators enables automated operation for standardized gentle dissociation or thorough homogenization on your benchtop. Start smart and preserve surface epitopes, as well as functionality of your cells of interest.

The gentleMACS™ Dissociators are a family of bench top instruments used for automated and standardized dissociation or homogenization of virtually any tissue. Viable single-cell suspensions are efficiently obtained by using our unique C Tubes in combination with our tissue-specific enzyme kits, whereas thorough homogenates are easily obtained by using the unique M Tubes. After processing, samples can be used for any cellular and molecular downstream analysis. Over 2,500 publications citing gentleMACS Technology proves that our devices can assist your research in multiple ways, such as
  • generation of highly viable single-cell suspensions in a fast, standardized, automated, and user-independent way,
  • ready-to-use tissue specific enzyme combinations with lot-to-lot consistency,
  • optimized protocols preserve cellular composition and surface epitopes,
  • single-use consumables minimize cross-contamination and allow easy disposal,
  • closed and sterile system reduces handling hazards.
ab859f88bae7de0da018fee384377d7c.png



Keep it fresh – store tissue and keep its primary state
  • The MACS® Tissue Storage Solution has been developed to allow an optimized storage of fresh organ and tissue samples without showing background effects like cell activation or apoptosis induction. It has been tested and validated on a variety of human and murine tissues including tumors, skin, heart, spleen, brain, and skeletal muscle. 
    bbe72a6a62916f35c66e42cb5f03a6a9.png
    Order no. Product Size
    130-100-008 MACS Tissue Storage Solution 100 mL

    • MACS Tissue Storage Solution represents a robust and convenient solution for short-term storage of different tissue samples and organs.
    • Cell viability, cellular composition, and activation status of cells are well preserved for at least 48 hours.
    • MACS Tissue Storage Solution prevents cellular stress responses, since changes in cellular stress-related gene expression levels were kept to a minimum compared to fresh sample material.
Be gentle – get viable cells with preserved epitopes
gentleMACS™ Technology delivers viable cells from solid tissues in a fast, standardized, and user-independent way, which preserves cellular composition and surface epitopes.
a8cac3272e1e3e4f24552b71d3f8c21c.png
Order no. Product
130-095-929 Tumor Dissociation Kit, Human
130-096-730 Tumor Dissociation Kit, Mouse
130-110-203 Multi Tissue Dissociation Kit 2
130-098-373 Neonatal Heart Dissociation Kit, mouse and rat
130-105-807 Liver Dissociation Kit, mouse
130-095-927 Lung Dissociation Kit, mouse
130-105-737 Umbilical Cord Dissociation Kit, human
130-095-926 Spleen Dissociation Kit, mouse
130-097-410 Lamina Propria Dissociation Kit, mouse
130-092-628 Neural Tissue Dissociation Kit (P)
130-098-305 Skeletal Muscle Dissociation Kit, mouse and rat
130-101-540 Whole Skin Dissociation Kit, human

Clean it – remove cell aggregates and other unwanted material
Innovative cell strainers and cleaning reagents help you to tune your sample for your downstream application by the removal of cell aggregates, debris, or other unwanted material, such as myelin, dead cells, or erythrocytes.


gentleMACS™Technology
gentleMACS Technology allows fully automated tissue dissociation in a closed and sterile system to generate tissue lysates or viable single-cell suspensions with high viability and preserved surface epitopes. With the unique combination of alternating incubation time of enzymatic digestion and mechanical disruption, enzyme activity and shearing forces are lowered to a minimum. This makes gentleMACS Technology the most gentle and convenient method for standardized and reproducible tissue dissociation.
gentleMACS™ Dissociators—Automated tissue dissociation on your bench
The gentleMACS, gentleMACS Octo Dissociators and gentleMACS Octo Dissociator with Heaters offer reliable tissue dissociation and thorough homogenization with pre-defined programs and
parallel sample processing. The gentleMACS can process two samples in parallel with over 40 predefined programs. The gentleMACS Octo can process eight samples in parallel or independently and allows for the creation of user-defined programs. The gentleMACS Octo Dissociator with Heaters extends the basic features of the gentleMACS Octo Dissociator for maximum convenience, flexibility, and efficiency.

04e47a631fc2641ad13b0ff4af7aab80.jpg       

Order no. Product Size
130-093-235 gentleMACS Dissociator 2 samples, semi-automated
130-095-937 gentleMACS Octo Dissociator 8 samples, semi-automated
130-096-427 gentleMACS Octo Dissociator with Heaters 8 samples with heater, fully-automated



gentleMACS™ Tubes

The gentleMACS Tube is a central component of gentleMACS Technology. Each element of the tube has been engineered to ensure the highest performance in the dissociation or homogenization of your tissue samples. The cap has a rotor-stator-system to apply
gentle mechanical shearing to tissue.
Dedicated tubes for specific applications:
• Tissue dissociation: Use the purple-cap C Tube for gentle tissue disruption to get viable single-cell suspensions for cell separation, cell culture, and cell analysis experiments.
• Tissue homogenization: Choose the orange-cap M Tube to achieve thorough sample homogenization for subsequent molecular and
microbiology analysis
e0c2e7d28ec703ff051f880701dfac7b.jpg              
Order no. Product
130-093-237 gentleMACS C Tubes (25×), sterile, single packed
130-096-334 gentleMACS C Tubes (100×), sterile, 25 tubes per bag
130-093-236 gentleMACS M Tubes (25×), sterile, single packed
130-096-335 gentleMACS M Tubes (100×), sterile, 25 tubes per bag
130-094-392 gentleMACS M Tubes with Strainer (50×), 50 tubes per bag with 600μm mesh strainer
MACSmix™ Tube Rotator
The MACSmix Tube Rotator is a helpful tool for the enzymatic digestion steps during tissue dissociation with a gentleMACS Dissociator. It is a versatile instrument powered by rechargeable batteries operating independently of a permanent power supply. It is suitable for a temperature range of 2 °C to 42 °C and can be placed in a refrigerator or incubator.
6d7311eec349bbd10f9a440060a2faf5.png
Order no. Product Size
130-090-753 MACSmix Tube Rotator Tube rack for tubes from 0.5 mL to 50 mL in size

Smart strainers and filters
MACS® SmartStrainers can be used for the removal of larger particles from cell suspensions of dissociated
tissue or blood samples:
  • Improved ventilation during filtration avoids clogging of the strainers
  • Easily fit onto standard 15 mL and 50 mL conical tubes
  • Various mesh sizes are available, including 30, 70, and 100 µm to fit your specific application
Pre-Separation Filters are designed for effective and easy removal of cell aggregates from single-cell suspensions after labeling with MACS MicroBeads or antibodies. Using the filters ensures optimal flow within cell separation columns and in flow cytometers.

c7a000981c37c23eab9d870868ae4d74.png

Strainer Order no. Size Remarks
30 μm (Yellow) 130-098-458 50 filters sterile, single-packed
130-110-915 4 x 25 filters sterile packed as 4x25 pieces
70 μm (Purple) 130-098-462 50 filters sterile, single-packed
130-110-916 4 x 25 filters sterile packed as 4x25 pieces
100 μm (Orange) 130-098-463 50 filters sterile, single-packed
130-110-917 4 x 25 filters sterile packed as 4x25 pieces
Dead Cell Removal Kit
The Dead Cell Removal Kit is a fast and straightforward way of eliminating dead cells from cell cultures or tissue preparations. The Dead Cell Removal Kit contains ready-to-use MicroBeads and Binding Buffer for the magnetic labeling of cell debris, dead cells, and dying cells. The magnetically labeled material is removed by magnetic separation and pure, viable cells are obtained within 25 minutes.
The Dead Cell Removal Kit has been successfully used for the following applications:
Removal of dead cells prior to MACS® Separation of cells
  • Reduction of flow sorting time by elimination of dead cells
  • Elimination of dead cells from cell cultures
  • Improvement of immunocytochemical analysis of frozen cells
  • Preparation of viable, single-cell suspensions from tissue
  • Removal of dead cells from spermatozoa samples
  • Removal of dead cells prior to or following transfection of cells

4703c5ca044f617a0d1658c7c31b10d3.png